Welcome to the website of green ring technology (Tianjin) Co., Ltd!

  • 022-29398436

wtf-2000T AE-2的水中油分析仪

Agriculture, forestry, animal husbandry and fishery, industrial and mining enterprises, municipal engineering,hydrology

and water conservancy, scientific research institutions, real estate and construction industry, etc

wtf-2000T AE-2的水中油分析仪
The measurement based on fluorescence intensity is proportional to the concentration of TPH. Wtf-2000 series analyzers are designed for continuous automatic monitoring of the contents of petroleum hydrocarbons, natural and wastewater. The instrument consists of sample preparation unit and wtf-3000 luminescent detector. The sample preparation unit provides metered water feed and water and reagent flow switching, temperature control, stirring and mass exchange processes. The detector (or photocell) is used to detect the luminescence of water quality and petroleum hydrocarbons extracted from samples using patented chromatographic membrane technology. A special variant of the instrument wtf-2000-2c is modified to monitor the high risk of wastewater or natural water pollution. The analyzer is fixed and controlled by a built-in microprocessor or external PC. In a separate mode of operation, the selected response sequence can be assigned from the built-in keyboard. The firmware allows the distribution of any sequence of system component operations and changes in flow rate from 0.02 to 20 ml / min. The instrument is equipped with a 4-20 mA current loop and RS485 computer interface, customized report output and remote computer control. The concentration measurement results, up to 1000 values, are stored in the built-in memory and displayed on the screen in mg / L on the built-in color LCD touch screen. If the concentration of petroleum hydrocarbon exceeds the threshold level, the alarm mode is activated, and the relay station can trigger from the following command of the analyzer. The duration of a typical measurement cycle is 5-15 minutes (depending on the concentration of the sample being analyzed)
Product overview

The measurement based on fluorescence intensity is proportional to the concentration of TPH.

Wtf-2000 series analyzers are designed for continuous automatic monitoring of the contents of petroleum hydrocarbons, natural and wastewater. The instrument consists of sample preparation unit and wtf-3000 luminescent detector. The sample preparation unit provides metered water feed and water and reagent flow switching, temperature control, stirring and mass exchange processes. The detector (or photocell) is used to detect the luminescence of water quality and petroleum hydrocarbons extracted from samples using patented chromatographic membrane technology.

A special variant of the instrument wtf-2000-2c is modified to monitor the high risk of wastewater or natural water pollution. The analyzer is fixed and controlled by a built-in microprocessor or external PC. In a separate mode of operation, the selected response sequence can be assigned from the built-in keyboard. The firmware allows the distribution of any sequence of system component operations and changes in flow rate from 0.02 to 20 ml / min. The instrument is equipped with a 4-20 mA current loop and RS485 computer interface, customized report output and remote computer control. The concentration measurement results, up to 1000 values, are stored in the built-in memory and displayed on the screen in mg / L on the built-in color LCD touch screen. If the concentration of petroleum hydrocarbon exceeds the threshold level, the alarm mode is activated, and the relay station can trigger from the following command of the analyzer. The duration of a typical measurement cycle is 5-15 minutes (depending on the concentration of the sample being analyzed)

Product features
  • Principle of operation

    The measurement based on fluorescence intensity is proportional to the concentration of TPH.

    Features and advantages

    Continuous online monitoring;

    Digital data processing;

    High measurement rate;

    Low interference of suspended particles;

    Automatic cleaning to prevent contamination of the tester's hydraulic system;

    Programmable sampling rate of intake.

    Application examples

    Environmental monitoring:

    Production wastewater monitoring;

    Drained moisture monitoring for thermal and nuclear power plants;

    Monitoring reservoir potential pollution of petroleum hydrocarbon sources;

    Water quality monitoring is at the port.

    Process monitoring

    Quality control of water in technical lines of thermal power and nuclear power equipment;

    Monitoring of oil / lubricating material leakage;

    Monitoring of water preparation equipment;

    Water supply quality control heating power supply.

performance parameter

Devices and options

Wtf-2000-2 or wtf-2000-2c analytical instrument;

Accessories can be selected;

The set reagent is used to prepare the standard solution;

Set up the standard sample (hexane petroleum hydrocarbon solution);

Hydraulic (analysis of downpressure water);

Flow switching device and valve (for several sampling points)

technical service

According to the customer's requirements, our service engineers can install and debug the instruments of Jingxiang company on the customer's site. Negotiate and participate in the initial training of personnel, providing appropriate consideration to the specific needs of customers. Spare parts delivery and maintenance according to customer requirements (free of charge during the warranty period) to carry out the company's after-sales service.